EXOVA Warringtonfire-UKAS英国皇家认可委员会认可实验室
EXOVA Warringtonfire 威灵顿实验通过ISO17025实验室资质认可的实验室,同时为英国皇家认可委员会UKAS认可实验室,其UKAS编号为: UKAS 0249。EXOVA Warringtonfire 威灵顿实验还是欧盟公告号实验室成员,欧盟公告号为: NB 0833。
EXOVA Warringtonfire is able to provide a large number of reaction to fire testing services at our UKAS (UKAS 0249) accredited Warrington laboratory (ISO 17025). EXOVA Warringtonfire also as Notified Body No. 0833.
Exova在英国皇家认可委员会的认可编号为UKAS0249,目前轨道车辆上需要机车防火材料需要BS6853:1999标准要求的,由Exova实验室进行测试并出具测试报告和证书,在整个轨道车辆的业界人员都得到非常高的认可,确保工厂和贸易商的产品进行测试的数据的真实性和权威性。请资质认可的测试标准和项目请参考如下:
-BS 476 PART 3: 2004 - External Fire exposure roof test
-BS 476 PART 4:1970 - Non-combustibility test for materials
-BS 476 PART 5: 1979 - Method of test of ignitability
-BS 476 PART 6: 1989 - Method of test for propagation for products
-BS 476 PART 7: 1997 - Surface spread of flame test for materials
-BS 476 PART 11: 1982 - Method for assessing the heat emission from building materials
-BS 476 Part 12:1991 - Ignitability of Products by Direct Flame Impingement
-BS 476 Part 15:1992 - Method for measuring heat release of products - Cone Calorimeter
-BS 6401 - Smoke density test
-BS 6853: 1999: Annex B.1 - Toxicity test
-BS 6853: 1999: Annex B.2 - Determination Of Weighted Summation Of Toxic Fume, R. Area Based Test Method.
-BS 6853: 1999: Annex D.8.3 - Small Scale Smoke Test
-BS 6853: 1999: Annex D.8.4 - Panel Smoke Test
-BS 6853: 1999: Annex D.8.5 - Seating Smoke Test
-BS 6853: 1999: Annex D.8.6 - Flooring Smoke Test
-BS 6853: 1999: Annex D.8.7 - Cable Smoke Test
-BS EN 13823 (SBI) - Single Burning Item Test
-BS EN 1869 - Fire blanket test
-BS EN 50268 (Superseded by IEC 61034)
-BS EN 60695-11 Glow Wire test
-BS EN 60695-12 Glow Wire test
-BS EN 60695-13 Glow Wire test
-BS EN ISO 1182 - Non-combustibility test.
-BS EN ISO 11925-2 - Ignitability when subjected to Direct Flame Impingement
-BS EN ISO 1716 - Bomb Calorimeter
-BS EN ISO 4589: Part 2 - Oxygen Index Test
-BS EN ISO 4589: Part 3 - Elevated Oxygen Index Test
-BS EN ISO 4589: Part 3 – Appendix A Temperature Index Test
-BS EN ISO 9239-1 – Radiant Panel Floor Test
-BS 5803 (loft Insulation)
-NFP 92-501 - Epiradiateur
-NFP 92-503 - Electric Burner Test
-NFP 92-504 - Rate of Spread of Flame test
-NFP 92-505 - Dripping Test
-NFX 10-702 - Smoke Density Test
-NFX 70-100 - Mass Based Toxicity Test
-F-Rating summary report in accordance with NFF 16-101
-DIN 4102: Part 7 – Roof test
-ISO 5659-2: 2006 - Determination of Specific Optical Density
-ISO 5660-1 - Cone Calorimeter
-ISO 9705:1993 - Full-scale room test for surface products.
-ISO 5658 - Surface Spread of Flame Test.
-EN 1869 - Fire blanket test
-European Directive 95/28/EC: Annex IV
-European Directive 95/28/EC: Annex V
-IMO A.653 (16) As Amended By IMO Resolution MSC 61(67): Annex 1, Part 5
-IMO Resolution A.652 (16) - Recommendation on Fire Test Procedures for upholstered furniture
-IMO Resolution A 471 (Xll) as amended by A.563 (14) - Recommendation on test method for determining the resistance to flame of vertically supported textiles and films
-IMO Resolution A.688 (17) - Fire Test Procedures for ignitability of bedding components.
-IMO Resolution MSC 40(64) - Full-scale room test for surface products.
-IMO Resolution MSC 61(67): Annex 1, Part 1 - Non-combustibility test.
-IMO Resolution MSC 61(67): Annex 1, Part 2 - Smoke and Toxicity test
MSC / Circ 1006
-ASTM E648-03 – Radiant Panel Floor Test
-ASTM E662-03 – Smoke Density Test
-NES 711 – Smoke Density Test
-NES 713 – Toxic Gas Emissions
-NFX 10-702 - Smoke Density Test
-NFX 70-100 - Mass Based Toxicity Test
-BS EN 60684-2 fluorine content
-ABD 0031 Smoke and toxicity
-IEC 50267-2: Parts 1, 2 & 3 – Gas emission test
-IEC 60754: Part 1 – Gas emission test
-IEC 60754: Part 2 – Gas emission test
-CERTIFIRE DTS 63 – Temporary Protective Coverings Test
Package includes all tests specified in DTS 63
Mining Grating Test
(In-house Test Procedure)
PAS 017 Amended 14 September 1999
Clause 10.1 - Flammable Liquid Test
Mudguard Testing -
(In-house Test Procedure)
WFR TP 002: January 1999
BS 476:PART 3: 2004
External Fire exposure roof test
DD ENV 1187: Test 1
DD ENV 1187: Test 2
DD ENV 1187: Test 4
ENV 1187 Test 4 / BS 476: Part 3: 2004 combination test
DIN 4102: Part 7
NORD TEST NT 006
UIC 564-2 Appendix 5
UIC 564-2 Appendix 11
UIC 564-2 Appendix 12
UIC 564-2 Appendix 13
CEN TS 45545-2 Annex A CEN TS 45545-2 Annex B
Annex A with Annex B package
CEN TS 45545-2 Annex C (Smoke and Toxicity Chamber Test)
ISO 5659-2 in one mode only (as required in prCEN TS 45545-2 where no toxicity measurement is required)
IEC 332-1 - Small Scale Cable Propagation Test
IEC 50267-2: Parts 1, 2 & 3 – Gas emission test
IEC 60754: Part 1 – Gas emission test
IEC 60754: Part 2 – Gas emission test