EXOVA Warringtonfire-UKAS 0249
EXOVA Warringtonfire is able to provide a large number of reaction to fire testing services at our UKAS (UKAS 0249) accredited Warrington laboratory (ISO 17025). EXOVA Warringtonfire also as Notified Body No. 0833.
Please refer to the following standards and items for qualification testing:
-BS 476 PART 3: 2004 - External Fire exposure roof test
-BS 476 PART 4:1970 - Non-combustibility test for materials
-BS 476 PART 5: 1979 - Method of test of ignitability
-BS 476 PART 6: 1989 - Method of test for propagation for products
-BS 476 PART 7: 1997 - Surface spread of flame test for materials
-BS 476 PART 11: 1982 - Method for assessing the heat emission from building materials
-BS 476 Part 12:1991 - Ignitability of Products by Direct Flame Impingement
-BS 476 Part 15:1992 - Method for measuring heat release of products - Cone Calorimeter
-BS 6401 - Smoke density test
-BS 6853: 1999: Annex B.1 - Toxicity test
-BS 6853: 1999: Annex B.2 - Determination Of Weighted Summation Of Toxic Fume, R. Area Based Test Method.
-BS 6853: 1999: Annex D.8.3 - Small Scale Smoke Test
-BS 6853: 1999: Annex D.8.4 - Panel Smoke Test
-BS 6853: 1999: Annex D.8.5 - Seating Smoke Test
-BS 6853: 1999: Annex D.8.6 - Flooring Smoke Test
-BS 6853: 1999: Annex D.8.7 - Cable Smoke Test
-BS EN 13823 (SBI) - Single Burning Item Test
-BS EN 1869 - Fire blanket test
-BS EN 50268 (Superseded by IEC 61034)
-BS EN 60695-11 Glow Wire test
-BS EN 60695-12 Glow Wire test
-BS EN 60695-13 Glow Wire test
-BS EN ISO 1182 - Non-combustibility test.
-BS EN ISO 11925-2 - Ignitability when subjected to Direct Flame Impingement
-BS EN ISO 1716 - Bomb Calorimeter
-BS EN ISO 4589: Part 2 - Oxygen Index Test
-BS EN ISO 4589: Part 3 - Elevated Oxygen Index Test
-BS EN ISO 4589: Part 3 – Appendix A Temperature Index Test
-BS EN ISO 9239-1 – Radiant Panel Floor Test
-BS 5803 (loft Insulation)
-NFP 92-501 - Epiradiateur
-NFP 92-503 - Electric Burner Test
-NFP 92-504 - Rate of Spread of Flame test
-NFP 92-505 - Dripping Test
-NFX 10-702 - Smoke Density Test
-NFX 70-100 - Mass Based Toxicity Test
-F-Rating summary report in accordance with NFF 16-101
-DIN 4102: Part 7 – Roof test
-ISO 5659-2: 2006 - Determination of Specific Optical Density
-ISO 5660-1 - Cone Calorimeter
-ISO 9705:1993 - Full-scale room test for surface products.
-ISO 5658 - Surface Spread of Flame Test.
-EN 1869 - Fire blanket test
-European Directive 95/28/EC: Annex IV
-European Directive 95/28/EC: Annex V
-IMO A.653 (16) As Amended By IMO Resolution MSC 61(67): Annex 1, Part 5
-IMO Resolution A.652 (16) - Recommendation on Fire Test Procedures for upholstered furniture
-IMO Resolution A 471 (Xll) as amended by A.563 (14) - Recommendation on test method for determining the resistance to flame of vertically supported textiles and films
-IMO Resolution A.688 (17) - Fire Test Procedures for ignitability of bedding components.
-IMO Resolution MSC 40(64) - Full-scale room test for surface products.
-IMO Resolution MSC 61(67): Annex 1, Part 1 - Non-combustibility test.
-IMO Resolution MSC 61(67): Annex 1, Part 2 - Smoke and Toxicity test
MSC / Circ 1006
-ASTM E648-03 – Radiant Panel Floor Test
-ASTM E662-03 – Smoke Density Test
-NES 711 – Smoke Density Test
-NES 713 – Toxic Gas Emissions
-NFX 10-702 - Smoke Density Test
-NFX 70-100 - Mass Based Toxicity Test
-BS EN 60684-2 fluorine content
-ABD 0031 Smoke and toxicity
-IEC 50267-2: Parts 1, 2 & 3 – Gas emission test
-IEC 60754: Part 1 – Gas emission test
-IEC 60754: Part 2 – Gas emission test
-CERTIFIRE DTS 63 – Temporary Protective Coverings Test
Package includes all tests specified in DTS 63
Mining Grating Test
(In-house Test Procedure)
PAS 017 Amended 14 September 1999
Clause 10.1 - Flammable Liquid Test
Mudguard Testing -
(In-house Test Procedure)
WFR TP 002: January 1999
BS 476:PART 3: 2004
External Fire exposure roof test
DD ENV 1187: Test 1
DD ENV 1187: Test 2
DD ENV 1187: Test 4
ENV 1187 Test 4 / BS 476: Part 3: 2004 combination test
DIN 4102: Part 7
NORD TEST NT 006
UIC 564-2 Appendix 5
UIC 564-2 Appendix 11
UIC 564-2 Appendix 12
UIC 564-2 Appendix 13
CEN TS 45545-2 Annex A CEN TS 45545-2 Annex B
Annex A with Annex B package
CEN TS 45545-2 Annex C (Smoke and Toxicity Chamber Test)
ISO 5659-2 in one mode only (as required in prCEN TS 45545-2 where no toxicity measurement is required)
IEC 332-1 - Small Scale Cable Propagation Test
IEC 50267-2: Parts 1, 2 & 3 – Gas emission test
IEC 60754: Part 1 – Gas emission test
IEC 60754: Part 2 – Gas emission test