Fire safety standards are an essential component in building reliable structures. One such standard is ASTM E814, which is specifically designed to assess the fire resistance of penetration firestop systems.

Understanding this standard and its role in evaluating the durability of firestop systems is crucial to ensuring the materials and assemblies used in building design and construction can withstand exposure to fire.

What Is ASTM E814?

ASTM E814, also known as the Standard Test Method for Fire Tests of Penetration Firestop Systems, is a test standard developed by ASTM International to evaluate the fire resistance of various building materials and assemblies.

Specifically, ASTM E814 is designed to assess the performance of penetration firestop systems, which is essential when it comes to preventing the spread of fire through openings in walls, floors, and ceilings.

The standard consists of two different tests: the time-temperature fire test and the hose stream test. Additionally, each firestop system has two ratings: the F rating and the T rating.




ASTM E814 Testing Process

The ASTM E814 test involves subjecting penetration firestop systems to controlled fire conditions to measure their effectiveness in preventing the passage of flames, smoke, and hot gases. The components of the test include:

Specimen: The specimen represents the firestop system that is being evaluated and is installed within a test structure.
Furnace: The furnace is used to expose the specimen to a standardized fire curve, which simulates a real-world fire scenario.
Thermocouples: The temperature measurement devices monitor the heat generated during the test.
This evaluation provides valuable data on the fire resistance capabilities of building materials and assemblies and aids in developing and implementing effective fire safety measures in construction projects.

Common Challenges and Considerations in ASTM E814 Testing

While the ASTM E814 is essential for evaluating the fire safety of structures, various challenges need to be addressed during the fire testing process.

One such challenge is making sure that the test specimens accurately represent real-world applications. If there are inconsistencies in installation or deviations from the specifications of a manufacturer, this can negatively impact the reliability of the test results.

The test also needs to account for factors like the types of building materials and the joint configurations, making it crucial to carefully design and execute the testing protocol.

Another consideration is the need for qualified personnel to conduct the ASTM E814 tests. For the most accurate results, you’ll want to employ skilled technicians, engineers, and testing laboratories who have extensive experience in fire testing methods like the team at NGC Testing Services.

Don’t forget — whoever you choose to run your ASTM E814 test also needs to provide proper documentation of the test procedures and results.
 

ASTM E814 vs UL 1479

Another important standard in the fire testing of penetration firestop systems is UL 1479. While similar to the ASTM E814, there are notable differences in their testing methods and applications.

Both test standards use a specific test sample setup and standardized furnace time-temperature curve to assess the through-penetration firestop system''s ability to resist the passage of heat and flame, while maintaining its structural integrity when exposed to fire. That said, UL 1479 has the option for two additional ratings — an L Rating (from air leakage test) and a W Rating (from water leakage test).

Both ASTM E814 and UL 1479 contribute significantly to the development and implementation of effective fire safety measures. Most professionals consider both standards when assessing firestop systems to ensure a thorough understanding of their performance characteristics and compliance with industry requirements.



Safeguard Your Structures With Reliable Fire Testing

Through its rigorous evaluation of flame through, temperature rise, and structural integrity, the ASTM E814 standard gives reliable insights into the materials and assemblies used in buildings and whether they can withstand exposure to fire.

Finding a reputable company with expertise and a skilled team is essential when conducting the ASTM E814 test; errors in testing or analyzing results can lead to unreliable structures that put residents in danger in case of a fire.